Nominal voltage (III/3) | 800V |
Rated impulse voltage (III / 3) | 8kV |
Rated current | 25A |
Width | 5,7 mm / 0.224 inci |
Height | 4,1 mm / 0.161 inci |
Depth | 18,5 mm / 0.726 inci |
Jumper assignment | 1-2 |
Note (material data) | Information on material specifications can be found here |
Color | gri deschis |
Material group | I |
Insulation material (main housing) | Polyamide (PA66) |
Flammability class per UL94 | V0 |
Fire load | 0,005MJ |
Weight | 0,7g |
Test specification Railway applications – Rolling stock – Electronic equipment |
DIN EN 50155 (VDE 0115-200):2022-06 |
Test procedure Railway applications – Rolling stock equipment – Shock and vibration tests |
DIN EN 61373 (VDE 0115-0106):2011-04 |
Spectrum/Installation location | Service life test, Category 1, Class A/B |
Function test with noise-like vibration | Test passed according to Section 8 of the standard |
Frequency | f1 = 5 Hz to f2 = 150 Hz |
Acceleration | 0.101g (highest test level used for all axes) |
Test duration per axis | 10 min. |
Test directions | X, Y and Z axes |
Monitoring for contact faults/interruptions | Passed |
Voltage drop measurement before and after each axis | Passed |
Simulated service life test through increased levels of noise-like vibration | Test passed according to Section 9 of the standard |
Frequency | f1 = 5 Hz to f2 = 150 Hz |
Acceleration | 0.572g (highest test level used for all axes) |
Test duration per axis | 5 h |
Test directions | X, Y and Z axes |
Extended test scope: Monitoring for contact faults/interruptions | Passed |
Extended test scope: Voltage drop measurement before and after each axis | Passed |
Shock test | Test passed according to Section 10 of the standard |
Shock form | Half sine |
Acceleration | 5g (highest test level used for all axes) |
Shock duration | 30 ms |
Number of shocks per axis | 3 pos. und 3 neg. |
Test directions | X, Y and Z axes |
Extended test scope: Monitoring for contact faults/interruptions | Passed |
Extended test scope: Voltage drop measurement before and after each axis | Passed |
Vibration and shock stress for rolling stock equipment | Passed |